Home/Resources/Videos/Dust in a cleanroom
inShare on LinkedIn
Video · Laboratories

Medicine dust in a cleanroom.

CFD simulation of a pharmaceutical cleanroom: the streamlines in the room, the air velocities along the production line, then the cloud of dust emitted by a machine.

Updated on 25 November 2026

Video
CFD simulation
Duration
1 min 00
Year
2023
Location
France
Typology
Cleanroom
Key takeaway

In one minute, we see where dust escapes from a pharmaceutical production line and how the air in the room can carry it.

Key moments in the video

Click a passage to play it in the player.

What the video shows: where the dust comes from and where it goes

This video comes from EOLIOS's dust study in a pharmaceutical cleanroom, carried out for IPSEN. Two production lines operate side by side there.

Streamlines show the path of the air between the supply and return vents, then a velocity plane follows the production line. Finally, the video shows the cloud of dust escaping from a machine.

Where does this video come from? The risk of contamination between two lines

The 832 m³ cleanroom is served by 8 supply vents and 16 returns. The question was whether dust from one line could contaminate the other.

Definition · Cleanroom

A room in which the concentration of airborne particles is controlled by suitable filtration and air distribution. It protects the products and, sometimes, the operators.

EOLIOS carried out an on-site smoke test audit, CFD particle tracking and velocity measurements, then sized dust extraction systems.

View the full study: cleanroom dust study

The video and the study

The video shows the flows and the dust emission. The full study locates the leaks, assesses the contamination risk and presents the extraction systems sized.

View the study results: cleanroom dust study
FAQ

Frequently asked questions

The video, the dust and the link with the cleanroom study.

What exactly does this video show?

A CFD simulation of a pharmaceutical cleanroom: streamlines, velocities along the line and a cloud of dust emitted by a machine.

What do the colours mean?

They represent air velocity: red for fast air, blue for calm air. The particle cloud is coloured by concentration.

How was the simulation checked?

Through an on-site smoke test audit before the study, then an acceptance smoke test after the extraction systems were installed.

How big is the room?

832 m³, with 8 supply vents and 16 air returns.

Where can I find the study results?

The leaks located and the extraction systems sized are presented in the full cleanroom study.

Explore the field

Laboratories: continue exploring.

CFD expertise, delivered projects and technical dossiers: the whole Laboratories field in one place.

CFDExpert engineers
20+Countries
R&DResearch & innovation
Contact

A cleanroom or a contamination challenge to study?

The simplest thing is to talk it through together. Our engineers reply with an initial technical read.