Home/Resources/Videos/Temperatures at 1.50 m, fire with spread
inShare on LinkedIn
Video · Data Center

Temperatures at 1.50 m during a spreading fire.

Fire simulation in a data hall in Warsaw: a temperature plane at 1.50 m above the floor, seen from above, follows the heat as the fire reaches neighbouring racks.

Updated on 25 November 2026

Video
CFD simulation
Duration
1 min 15
Year
2025
Location
Warsaw, Poland
Typology
Data Center
Key takeaway

In just over a minute, we see how far the heat from a spreading fire reaches the height of responders in a data hall.

Key moments in the video

Click a passage to play it in the player.

What the video shows: the heat when the fire spreads

This video comes from EOLIOS's smoke control study of a data hall in Warsaw. It presents a scenario in which the fire spreads to neighbouring racks.

A temperature plane placed 1.50 m above the floor is seen from above. We follow the hot zone that starts in one corner of the room, reaches the neighbouring aisles and then the technical area. The same view exists for a fire without spread.

Where does this video come from? Smoke control in a high-density data hall

As part of the construction of a new data center with around 400 high-density racks, EOLIOS assessed the safety conditions for responders, including firefighters, in the event of a fire in an IT room.

Definition · Spread

The passage of fire from one rack to its neighbours. It increases the power of the fire and the amount of heat and smoke produced.

The data hall was modelled in Fire Dynamics Simulator (FDS) for several fire positions, with and without spread to neighbouring racks, in order to validate the smoke control system.

View the full study: smoke control study of a data hall in Warsaw

The video and the study

The video shows a scenario with spread. The full study derives from it the inaccessible zones and the intervention conditions, with and without smoke control.

View the study results: smoke control study of a data hall in Warsaw
FAQ

Frequently asked questions

The video, fire spread and the link with the smoke control study.

What exactly does this video show?

A fire simulation in a data hall: a temperature plane at 1.50 m above the floor, seen from above, for a fire that reaches neighbouring racks.

What do the colours mean?

They represent temperature: from blue for cool air to red for the hottest air.

Why compare with and without spread?

Spread changes the power of the fire. The two cases bracket the situations the emergency services may face.

Which software was used for the simulation?

Fire Dynamics Simulator (FDS), a fire simulation tool developed by NIST.

Where can I find the study results?

The inaccessible zones and the intervention conditions are presented in the full study of the data hall in Warsaw.

Explore the field

Data Center: continue exploring.

CFD expertise, delivered projects and technical dossiers: the whole Data Center field in one place.

CFDExpert engineers
20+Countries
R&DResearch & innovation
Contact

Want to see your project simulated?

The simplest thing is to talk it through together. Our engineers reply with an initial technical read.