Home/Resources/Videos/Temperature isosurface during a fire
inShare on LinkedIn
Video · Data Center

The hot air volume of a data hall fire.

Fire simulation in a data hall in Warsaw: a temperature isosurface envelops all the air above a given threshold and shows the hot volume spreading through the room.

Updated on 25 November 2026

Video
CFD simulation
Duration
1 min 15
Year
2025
Location
Warsaw, Poland
Typology
Data Center
Key takeaway

In just over a minute, we see at a glance how much of the data hall is filled by the hot air from a fire, and how fast it grows.

Key moments in the video

Click a passage to play it in the player.

What the video shows: the hot air volume of a fire

This video comes from EOLIOS's smoke control study of a data hall in Warsaw. It follows one of the fire scenarios studied in the room.

A temperature isosurface connects all the points at the same temperature. Everything it envelops is hotter than that threshold. We see the hot air volume appear near the fire and then spread through part of the room.

Where does this video come from? Smoke control in a high-density data hall

As part of the construction of a new data center with around 400 high-density racks, EOLIOS assessed the safety conditions for responders, including firefighters, in the event of a fire in an IT room.

Definition · Temperature isosurface

A surface connecting all the points at the same temperature. In a fire, it marks out the volume where the air exceeds a given threshold.

The data hall was modelled in Fire Dynamics Simulator (FDS) for several fire positions, with and without spread to neighbouring racks, in order to validate the smoke control system.

View the full study: smoke control study of a data hall in Warsaw

The video and the study

The video shows the extent of the hot air. The full study compares the fire positions, the cases with spread and the effect of smoke control.

View the study results: smoke control study of a data hall in Warsaw
FAQ

Frequently asked questions

The video, the isosurface and the link with the smoke control study.

What exactly does this video show?

A fire simulation in a data hall: a temperature isosurface shows the volume of hot air spreading through the room.

What do the colours mean?

The surface is coloured by temperature: orange and red mark the hottest air.

How does it differ from a temperature section?

A section shows one plane. The isosurface shows the whole volume above a threshold.

Which software was used for the simulation?

Fire Dynamics Simulator (FDS), a fire simulation tool developed by NIST.

Where can I find the study results?

The comparison of scenarios and the effect of smoke control are presented in the full study of the data hall in Warsaw.

Explore the field

Data Center: continue exploring.

CFD expertise, delivered projects and technical dossiers: the whole Data Center field in one place.

CFDExpert engineers
20+Countries
R&DResearch & innovation
Contact

Want to see your project simulated?

The simplest thing is to talk it through together. Our engineers reply with an initial technical read.