A CFD simulation flyover of two hyperscale data centers: the wind flows around the buildings, the hot discharges from the roofs rise in plumes, and we follow the flows that can carry this hot air back towards the air intakes.
Updated on 25 November 2026
Five minutes flying over an external CFD calculation: the wind around two hyperscale data centers, the plumes from their rooftop discharges and the flows through which hot air can return. These visualisations are used to identify recirculation risks, a cause of overheating for the cooling systems.
Click a passage to play it in the player.
This video comes from the external CFD study of two hyperscale data centers, DC15.1 and DC15.2, in Italy. The camera flies over the site and through the calculation: each streamline follows the path of an air particle, coloured from blue (cool air) to red (hot air).
We see the incoming wind flowing around the buildings, then the hot discharges from the rooftop equipment forming plumes that rise and disperse. In places, hot lines fold back down and run along the buildings: this is the type of flow the study had to identify, because it can carry hot air back towards the air intakes.
In a hyperscale data center, the density of IT equipment means a great deal of heat must be removed, discharged by a series of units grouped on the roof. EOLIOS was commissioned to check whether these discharges, and the plume from the generators, could contaminate the intake air through recirculation.
A phenomenon in which the hot air discharged by a unit is drawn back in by a nearby air intake. The supply air heats up, and the cooling systems lose efficiency.
A digital twin of the site was built: buildings, rooftop equipment, terrain and wind effect, wall temperatures, thermal draught of the installations. The simulation calculates temperatures and flows at every point in space, which is what this flyover shows.
View the full study: external CFD simulation of data centers DC15.1 and DC15.2This flyover makes visible the plumes and flows the study analysed to locate the recirculation zones. It also shows the value of CFD from the design stage, to position discharges and air intakes knowing how the air actually behaves around the site. The zones identified are detailed in the full study.
View the study results: external CFD simulation of data centers DC15.1 and DC15.2The video, the streamlines and the link with the recirculation study.
A flyover of an external CFD simulation of two hyperscale data centers. The streamlines show the path of the air around the site: the wind flowing around the buildings and the hot plumes discharged by the rooftop equipment.
It is the path followed by an air particle in the calculated flow. By drawing a large number of lines, you can see at a glance where the air comes from, where it accelerates and where it swirls.
Because cooling equipment and generators discharge their heat outdoors, often on the roof. Depending on the wind and the layout of the buildings, this hot air can return towards the air intakes and reduce cooling efficiency.
The streamlines are coloured by temperature: blue for cool outside air, red for air heated by the equipment discharges.
The recirculation zones located and the improvement options are presented in the full study of data centers DC15.1 and DC15.2.