Smoke and visibility at 1.50 m in a data hall on fire.

Fire simulation in a data hall in Warsaw: a smoke density plane at 1.50 m above the floor, seen from above, shows the smoke filling the room and how much visibility remains.

Updated on 25 November 2026

Video
CFD simulation
Duration
1 min 15
Year
2025
Location
Warsaw, Poland
Typology
Data Center
Key takeaway

In just over a minute, we see the smoke from a fire reach face height across a large part of the data hall.

Key moments in the video

Click a passage to play it in the player.

What the video shows: smoke at responder height

This video comes from EOLIOS's smoke control study of a data hall in Warsaw. It follows the smoke at the height at which visibility for the people intervening is assessed.

A smoke density plane placed 1.50 m above the floor is seen from above. The denser the smoke, the lower the visibility. We see the smoke appear in one corner of the room, fill the aisles and then clear in places.

Where does this video come from? Smoke control in a high-density data hall

As part of the construction of a new data center with around 400 high-density racks, EOLIOS assessed the safety conditions for responders, including firefighters, in the event of a fire in an IT room.

Definition · Visibility

The distance at which an object can be made out through smoke. It depends on smoke density and is used as a criterion for judging whether responders can move forward.

The data hall was modelled in Fire Dynamics Simulator (FDS) for several fire positions, with and without spread to neighbouring racks, in order to validate the smoke control system.

View the full study: smoke control study of a data hall in Warsaw

The video and the study

The video shows the smoke for one scenario. The full study compares visibility depending on the fire position, spread and smoke control.

View the study results: smoke control study of a data hall in Warsaw
FAQ

Frequently asked questions

The video, the smoke and the link with the smoke control study.

What exactly does this video show?

A fire simulation in a data hall: a smoke density plane at 1.50 m above the floor, seen from above.

What do the colours mean?

Blue corresponds to air with little smoke, dark red to dense smoke and therefore low visibility.

Why follow the smoke and not just the heat?

It is carried by air movements well beyond the hot zone. It is often what limits intervention.

Which software was used for the simulation?

Fire Dynamics Simulator (FDS), a fire simulation tool developed by NIST.

Where can I find the study results?

Visibility for each scenario and the effect of smoke control are presented in the full study of the data hall in Warsaw.

Explore the field

Data Center: continue exploring.

CFD expertise, delivered projects and technical dossiers: the whole Data Center field in one place.

CFDExpert engineers
20+Countries
R&DResearch & innovation
Contact

Want to see your project simulated?

The simplest thing is to talk it through together. Our engineers reply with an initial technical read.