CFD simulation of the wind risk at a Leroy Merlin store: aerial footage of the real site, then velocity planes, streamlines and pressures on the loading and storage areas.
Updated on 25 November 2026
In just over a minute, we see why the storage and loading areas of a large store are the most exposed. This is where the wind hampers movement, lifts light objects and can damage equipment.
Click a passage to play it in the player.
This video comes from the CFD wind risk study of Leroy Merlin stores in southern and south-western France, where wind is a real operating constraint. It starts with aerial footage of the site, then moves on to the calculation model.
We see in turn velocity planes, streamlines running along the façade and rushing towards the materials yard, and the wind pressure on the walls. The wind does not blow the same way everywhere: it concentrates on a few sensitive areas.
On a large commercial site, wind becomes a constraint as soon as it concentrates on work, circulation or storage areas. Materials yards and logistics accesses, often open, are particularly sensitive.
A screen that lets part of the air through instead of blocking it. It slows the wind over a long distance without creating vortices behind it as strong as those of a solid wall.
EOLIOS combined an on-site audit, a meteorological study, a reference wind defined according to the Eurocode and a CFD simulation of velocities and pressures, before making technical recommendations.
View the full study: securing a commercial site against wind riskThe video shows how the wind concentrates on the site. The full study compares the initial design and the optimised design, and presents the protection proposed for the storage areas.
View the study results: securing a commercial site against wind riskThe video, the risk areas and the link with the site security study.
Aerial footage of a store, then a CFD simulation of the wind on the site: velocity planes, streamlines and pressures on the loading and storage areas.
On the velocity planes and streamlines, red marks fast air and blue calm areas. On the walls, the colours represent wind pressure.
They are often open, facing outwards and located where the building channels the wind. Opening the doors can further increase the draughts.
It places the store in its surroundings, very open ground where nothing stops the wind before it reaches the building.
The comparison between the initial and optimised designs, and the proposed protection, are presented in the full commercial site study.
Explore our expertise, projects and technical papers to go further than the FAQ.
CFD expertise, delivered projects and technical dossiers: the whole Air & Wind field in one place.
The simplest thing is to talk it through together. Our engineers reply with an initial technical read.