Search
Close this search box.

Fine particle capture in a metro station

In a few words

EOLIOS carried out a CFD study in a Paris metro station to assess the effectiveness of fine particle sensors installed on the platforms.

Project

Fine particle capture in a metro station

Year

2023

Customer

SNCF - TRAPAPART

Location

France/Paris

Typology

Air & Wind

Continue browsing :

Our other projects :

Latest news:

Our activities :

Technical file :

Description of the project

The danger of poor air quality in underground rail spaces (Metro / RER stations)

Since the early 2000s, air quality measurements have shown that, on average, airborne particle concentrations in rail areas in France are three times higher than in urban outdoor air. The concentration of particulate matter measured in the air is often expressed in terms of PM10 and PM2.5.

These particles penetrate the respiratory tract, with the finest particles deposited directly in the pulmonary alveoli.
What’s more, the composition of fine particles observed in railway environments is quite different from that of outdoor air, with high concentrations of metallic elements, particularly iron, as well as elemental and organic carbon.
Specific to underground rail activity, this pollution is caused by wear and tear of materials due to train braking, friction between wheels and rails, and the resuspension of dust due to train movement.

Epidemiological and toxicological data suggest that there could be serious cardiorespiratory impacts, given the biological consequences observed in terms of inflammation, oxidative stress and cardiovascular activity in workers in charge of maintaining this type of infrastructure.
In view of these observations, ANSES confirms the need to reduce fine particle pollution in underground railway areas, and therefore to pursue actions in this direction, such as the study and improvement of ventilation in these environments.

Study on pollution in public transport: focus on particles generated by rail operations

Today, air quality is a major concern for our health on a global scale. Public transport is often presented as a greener alternative, as it reduces pollutant emissions per kilometer traveled. However, they are not totally pollution-free. The wear and tear of components used in rail operations, such as wheels, rails, ballast, pantographs, catenary and brakes, generates polluting particles.

These particles tend to accumulate more in underground rail enclosures due to the confinement effect. Unfortunately, studies on the impact of this pollution are still rare. That’s why Trapapart has launched a research project on the subject.

The problem of fine particles

Pollution levels in underground railway spaces: the containment effect and the accumulation of pollutants

Pollution levels in underground rail spaces are mainly caused by their confinement, which limits the air renewal needed to eliminate pollutants emitted by operating trains. As a result, older stations are more likely to accumulate pollution particles indoors.

The impact of outdoor air pollution on that of underground stations is not clearly defined; it largely depends on the specific architectural features of each underground transport system. Factors such as the type of ventilation (natural, forced, air-conditioned), the depth of the station (deeper stations are less sensitive to variations in outside air quality) and the number of entrances play an essential role.

capteur de particule fine
Illustration of a fine particle sensor

Seasonal variations in the weather also seem to influence pollution levels on the docks. It is important to note that the materials used in the construction of stations, rail infrastructure and rolling stock, subject to wear and abrasion, can contribute to the variability of particulate pollutants.

Study of passive systems to capture fine particles

Research into the impact of pollution on public transport: the Trapapart initiative

Traps TrapAparT traps reduce people’s exposure to harmful fine particles by equipping targeted areas, such as major urban thoroughfares and underground railway stations (metro), with pollution levels well above the thresholds recommended by the WHO for places with high human concentrations.

TrapAparT devices: a patented media for trapping fine particles in urban areas with high concentrations of people

The heart of the device consists ofa fine-particle adsorbent media patented by TrapAparTs patented fine particle adsorbing media, capable of trapping fine particles by bringing them into contact with the air using only natural air flows (wind and turbulence generated by vehicles). The media is regenerated by simply washing it with water at a frequency of around one month. The wash water is recovered and the pollutants removed.

The main aim of the study carried out by EOLIOS engineers is therefore to analyze air speeds and trajectories inside the station, in order to determine whether the devices installed on the platforms are effective in capturing the fine particles present in the atmosphere. This project is of great importance, as it aims to control the specific aeraulic phenomena that occur on the station platform. To this end, the study will focus on the application of CFD modeling to explore in detail the aeraulic principles inherent in the airflow generated by passing subways.

On-site audit

Audit of air movements and fine-particle concentration when subways arrive in the station

The aim of the audit is to carry out a series of measurements to study the air movements associated with the arrival of metros in the station. At the same time, it aims to assess the concentration of fine particles in the air. These surveys will be carried out exclusively on the quays and in the quayside technical area.

Prise de mesure dans le métro parisien - relevé des particules fines
Study of wind speeds under the roof in the wind turbine siting areas

Analysis of airflow velocities in underground stations: study of the effect of passing trains on airflow

EOLIOS engineers have observed that air current velocities vary according to the direction of the train, with lower maximum amplitudes when the train is travelling on the opposite platform. These speeds are influenced by factors such as braking time and train power. What’s more, the reduction in air speed as the train passes depends on the direction in which the train is moving (arriving or leaving the platform) and the duration of the passage. It should be noted that the measurements, carried out close to the platform in the intervention zone, led to significant slowing down of trains for safety reasons, resulting in deviations from normal traffic conditions.

CFD simulation

CFD modeling of subway station and trains

Computational Fluid Dynamics (CFD) is a numerical method used to study fluid flows in given environments. It enables the complex equations governing these flows to be solved numerically, since they cannot be solved analytically. By applying CFD to buildings, we can obtain the following information air velocities, pressures and temperatures in and around construction spaces. This helps designers to optimize ventilation and air-conditioning, taking into account factors such as building structure, internal heat gains and air-conditioning systems, to ensure optimum comfort.

To solve the partial differential equations, we need to define the boundary conditions for the calculation. These are established on the basis of on-site measurements and information supplied by the prime contractor. Boundary conditions determine the type of walls, flows (unidirectional inlet or outlet), parameters such as velocity, flow rate or mean static pressure, as well as surface coefficients if required to simulate heat transfer.

The model mesh, composed of around 10 million orthogonal structured fluid elements with refinement in key areas, is essential for the accuracy of the study, but can lead to long computation times.

The 3D model of the station was drawn up using the plans supplied, using the simplified geometry of the site and its surroundings. To guarantee the accuracy of the measurements, the tunnels on either side of the station were included in the model with a sufficient length to avoid any influence from the model’s boundary conditions.

In addition, to study the impact of the metro’s passage on the station’s thermoaerodynamics, a specific 3D model of the metro train was created. This approach makes it possible to explore in depth the interactions between the train and the station environment, contributing to a better understanding of thermal and aeraulic phenomena in this space.

Modélisation 3d d'une rame de métro pour la CFD
Study of the wind energy potential of different types of low speed wind turbines

CFD study of air movements in the metro station

The train’s passage generates lasting disturbances in its wake. These disturbances show that the air velocity follows a trajectory tangent to the media, which can be advantageous given their characteristics.

In motion, the landing gear induces drag at the rear. When a train moves, it creates a zone of overpressure at the front and a zone of depression at the rear. This results in a flow of air from the sides of the undercarriage towards the rear to compensate for the negative pressure, thus increasing the speed of the air at the rear compared with static air.

The pressure planes illustrate the propagation of the pressure wave caused by the approaching train. The initial flow is from left to right, then reverses once the train is in the station, particularly at the head of the train. The pressure difference at the head of the train causes a flow of air through the media, although this pressure delta is short-lived.

Play Video
CFD modeling of air velocities for a train entering a station

Vorticity is a pseudo-vector field that describes the local rotational motion of a medium. It allows us to visually identify areas of intense turbulence. Vorticity patterns reveal that regions close to the media experience disturbances, particularly after the train has passed.

Play Video
CFD modeling of vorticity effects for a train entering a station

Additional studies have made it possible to precisely define the performance levels of the capture systems. Optimization solutions, such as the development of deflectors have improved fine particle capture performance.

EOLIOS is thus able to work on cases involving the release of fine particles, and to help manufacturers optimize their installations and design prototypes.

Play Video
CFD modeling of vorticity effects in the catchment area

Additional studies have made it possible to precisely define the performance levels of the capture systems. Optimization solutions, such as the development of deflectors have improved fine particle capture performance.

EOLIOS is thus able to work on cases involving the release of fine particles, and to help manufacturers optimize their installations and design prototypes.

Continue to study the dispersion of fine particles in underground stations:

Video summary of the study

Play Video

Discover other projects

Comfort – Rooftop of a palace – Casablanca

Prototype – Natural ventilation chimney

Tour Liberté – La Défense

Impact of wind on a solar power plant

Cooling towers – ICPE

Pedestrian comfort study – La Défense

Confort au Vent – PSG training center

Wind study – La Défense

Fine particle capture in a metro station

Sharaan by Jean Nouvel resort

Air coolers – Critical study – Heat wave