Smoke control engineering (ISI)
Accueil » Smoke control » Smoke control engineering (ISI)
Smoke control engineering :
- Visibility through smoke
- Maximum air temperature study
- Evacuation study
- Smoke propagation in spaces
- Wall radiation temperature
- Flue gas temperature and velocity profile
- Fire scenario according to risk
- Wind effects taken into account
- Optimizing smoke extraction systems
Continue navigation :
Our latest news :
Read more :
Case study :
Our areas of expertise :
Smoke control engineering
Fire safety and smoke extraction system design: Ensuring occupant safety
It is imperative to design facilities with adequate occupant safety and compliance with fire safety regulations in mind.
Our studies help architects and engineers simulate fire and smoke propagation to design smoke extraction systems for buildings, subways and other facilities open to the public.
The aim is to assess and understand the airflow profile and smoke propagation over time in the space concerned during a fire.
The study also highlights possible design improvements by monitoring airflow patterns, identifying pockets of dead air, assessing average air age, fan projection and building air velocities.
The performance of the smoke extraction system can be evaluated using CFD analysis, and smoke movement, temperature and visibility profile can be studied under various fire scenarios.
At the same time, we may need to carry out evacuation studies to reinforce the relevance of the evacuation scenarios selected.
CFD simulation of smoke propagation over time
We produce :
- Regulatory calculation note
- Fire and smoke extraction simulations
- Transient calculation of smoke distribution
- Transient temperature calculations
- Optimization of regulatory, technical and organizational fire protection design
Optimizing fire protection and smoke extraction
When it comes to complex buildings, existing directives and regulations are sometimes too general to be able to reliably assess the interactions between a fire and the development of smoke gases. As a result, the technical solution may not be fully validated by regulations such as IT246 , andan unfavorable opinion may be issued by the inspection office even though the smoke extraction system is functional.
When creating a smoke extraction concept, we use calculation methods that take into account the interaction between :
- Room ventilation and fire location
- Smoke fire and blown air
- Fire smoke and exhaust air
- Thermal and ambient pressure
- The impact of an unfavorable wind
- Start-up time for mechanical systems
Numerical simulation is used to calculate smoke, temperature and pressure curves as a function of time.
- the height of the smoke layer (clearance)
- temperature distribution in spaces
- flue gas concentration distribution
- the temporal and spatial evolution of flue gas propagation
- Study of visibility through smoke
CFD simulation can be used to model complex buildings and spaces.
It can be used to model smoke development, temperature and pressure curves as a function of time.
In this way, we are able to justify the design of smoke extraction for complex buildings and large atria.
Modeling visibility through smoke
The ability to see through smoke defines the distance at which an evacuation sign can be seen from a smoke-filled environment. Our studies enable us to define this distance as a function of the resulting air flow, the type of fire, the location of the fire and the properties of the heat load.
This information helps designers to determine the location of exit signs in enclosed environments, and to check that clearances remain perfectly passable.
When smoke fills a room, the visibility of exit signs is vital for safe evacuation .
We provide the necessary justification to the inspection authorities
Thanks to fire and smoke extraction simulations, we can determine at an early stage which smoke extraction systems and various natural ventilation openings are compliant.
We analyze smoke nests in trapped areas and make structural and technical suggestions to keep escape routes smoke-free. With the help of videos, we can illustrate the propagation of smoke gases and thus agree on the necessary measures in consultation with all those involved in the design.
We organize discussions with the inspection authorities, so as to justify the design in terms of the standard’s interpretation. Our many years of experience in major projects are particularly advantageous in this context.
Smoke control engineering: on the same subject
Fire safety engineering
Find out more
Data Center Fire Simulation
Find out more
Dynamic modeling of the evacuation of people
Find out more